Troubleshooting a solar water pump

Most solar pump faults are one of a handful of problems: not enough voltage, no water at the intake, air in the line, a stuck float switch, or wear. Work through them in order from the panels to the outlet.

By the editors of SolarPoweredWaterPumps.comLast reviewed October 20262 min read

Short answerWork from the panels to the outlet: check voltage at the controller in full sun, then the float switch and any low-water probe, then the intake and the pipe for air or leaks. Most faults are low voltage, no water at the intake, air in the line, a stuck float or wear.

Affiliate links on this page. We may earn a commission if you buy through them, at no extra cost to you. That doesn't change what we recommend. How we make money.

Key takeaways

  • Work from the panels to the outlet: voltage, intake, air, float switch, wear.
  • A multimeter and a five-gallon bucket answer most questions in minutes.
  • If the water table has dropped, your total dynamic head has risen: recalculate.

Safety. Panels and batteries can deliver dangerous current. Follow NEC Article 690 and local code, and use a licensed electrician or well contractor where your state requires one.

Symptoms and causes

SymptomCheck firstThen
Will not start in full sunVoltage at the pump or controller with a meter; float switch positionBlown fuse, loose connector, controller fault, seized pump
Starts late, stops earlyArray voltage at low sun vs the pump's start voltageAdd a panel in series, or use a pump controller with MPPT
Runs but pumps nothingWater level vs intake; surface pump prime and foot valveAir leak on the suction side, worn diaphragm, broken drop pipe
Starts and stops repeatedlyDry-run probe tripping as the well draws downLower the pump, reduce flow, or accept cycling on a low-yield well
Less water than last yearShade, dirty panels, clogged intake screenWorn diaphragm or stator, falling water table, leak in the line
Pump runs, tank never fillsLeak or open valve between pump and tankHead now beyond the pump's curve (water level dropped)
Battery system dies overnightBattery state of charge at dusk; charge controller logsArray too small for the season; battery too cold to charge

Measuring is faster than guessing

A cheap multimeter answers most questions in minutes. Measure open-circuit voltage at the array, then voltage at the pump while it runs. A big drop between the two means undersized cable or a bad connection. For flow, time how long the outlet takes to fill a five-gallon bucket at midday: 60 divided by the seconds, times 5, is gallons per minute.

When it is the well

If flow drops and the pump checks out, measure the water level. Water tables move with drought and with neighbouring pumping. If the pumping level has fallen, the total dynamic head has risen, and the pump may now be near the end of its curve. Recalculate with the sizing calculator.

Next step

Put your own gallons, lift and pipe in and see every step of the working.

Open the sizing calculator