Skip to content
Wisconsin · modelled at Milwaukee

Solar water pumps in Wisconsin

Wisconsin averages 4.45 peak sun hours a day across the year, 39th of 51. The darkest month, Dec, gives 2.05 (43rd of 51 for winter sun); the brightest, Jun, gives 6.21. A pump that has to fill a trough in Dec needs 3.0 times the panels of one that only runs in Jun.

By the editors of SolarPoweredWaterPumps.comLast reviewed October 2026

Peak sun hours by month

kWh per square metre per day on a south-facing panel at 20 degrees in Milwaukee (43.04, -87.91). Source: NREL NSRDB via PVGIS v5.2.

Worked sizing for Wisconsin

The same two systems are worked for every state so you can compare. Both use 35% or 30% wire-to-water efficiency and a 0.75 array factor; change any input in the calculator.

SystemDesign sunFlowTDHPump inputPanelsTank
20 beef cattle, year-round (80 ft lift, 10 ft rise, 300 ft of 1 in poly)2.05 h3.25 gpm93 ft163 W220 W1,200 gal
Same well, grazing season April to October only3.72 h1.79 gpm91 ft88 W120 W1,200 gal
1,000 sq ft garden in summer, from a pond (8 ft suction, 15 ft rise, 200 ft of 3/4 in poly)6.02 h0.25 gpm23 ft4 W10 W267 gal

Panel figures are the floor from the arithmetic. Real systems usually carry 1.5 to 3 times this so the pump sits in the middle of its curve and the tank refills after cloudy days.

Run your own numbers. The sizing calculator shows every step, for your state, lift and pipe.

Open the calculator

What this means in Wisconsin

Wisconsin's winter sun is weak. A year-round direct-drive stock well works, but the array is large for the water it makes in Dec. Many owners size for the grazing season and haul or heat water in the darkest weeks, or add storage. Steeper winter tilt helps, and so does keeping panels clear of snow.

Related reading: winterizing, livestock watering and USDA cost share.